REXGEAR RLC load bank testing solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC/DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
RLC load banks applications
- UL1741 / IEEE1547.1 Compliance Test
- Battery bank system
- Energy storage system
- Energy meter loop load test
- Data center rack heat simulating
- PV system Inverter anti-islanding test
- Voltage regulator, rectifier aging load test
- Genset, UPS load bank commission testing
Remote Control by PC
RLC load banks loading elements (load bank types)
Alloy resistors, inductors & capacitors loading elements are combined used in RLC load bank as per clients’ need in different applications:
- Pure resistive AC load bank
- Pure resistive DC load bank
- RCD non-linear AC load bank
- Resistive & inductive combined AC load bank
- Resistive, inductive & capacitive combined AC load bank
Technical Specifications
Model | Resistive, Inductive & Capacitive AC Load Bank |
---|---|
Load Element | Stainless steel resistors, Inductor & Capacitor |
Load Voltage | 3φ4W+G, Y connection: 110/190V,115/200V, 120/208V,128/220V,132/230V,139/240V 220/380V, 230/400V, 240/415V, 254/440V, 265/460V, 277/480V (Or other load voltage upon request) |
Frequency | 50/60Hz |
Load Power | R (resistive power): upon request
L (inductive power): upon request C (capacitive power): upon request |
Minimum Load Steps | Resistive load step: 10W
Inductive load step: 10Var Capacitive loa step: 10Var (Or other load step upon request) |
Power Factor | PF=Leading & lagging 0-1.0 adjustable |
Load Accuracy | R: ±5%, L: ±10%, C: ±5% |
Digital Meter | voltage, current, active power, reactive power, apparent power, power factor, energy, frequency |
Mains Power Supply | 1 phase 2wire 50/60Hz: AC120V/220V/230V/240V 3 phase 4wire 50/60Hz: AC208V/380V/400V/415V |
2 Control Modes | 1- Manual control by push button
2- PC software remote control |
Wire Connections | Copper bus bar for wire connections |
Insulation Class | F |
Fan Noise | 75-90dB |
Cooling Mode | Force-air vertical or horizontal cooling |
Work Mode | Continuous work |
Protections | Overheating/buzzer alarm, overheating/over voltage/current protection, emergency stop button |
Ambient Temperature | 10℃~+50℃ |
Mobility | By wheels or stationary with forklift pocket |
Humidity | ≤95% |
Altitude | ≤2500 meters |
RLC load banks protections
Standard protections:
- Emergency pause operation: one-key stop loading
- Over temperature alarm/protection: alarm & remove load
- Fan interlock protection: loading available after fan activated
- Over voltage protection: alarm & remove load
Optional protections
- Blower thermal overload protection: alarm & remove load
- Short circuit protection by fuse (over current protection)
- Phase sequence protection (for fans with 3phase voltage)
- Or other functions as requested

RLC load bank control modes
Two control modes available for RLC load banks: The local panel control mode and the PC software remote control mode.
Local panel control mode available as below listed:
- By contactor
- By circuit breakerOr other switches as requested
PC software remote control
RLC load bank remote control communication protocol would be provided for clients’ integrating the load bank into the ATE system

Resistive, Inductive & Capacitive AC Load Bank (RLC)
RLC load banks are mostly used for inverter anti-islanding test experiments which meets the PV & grid inverter testing requirements for islanding prevention detection, work efficiency test, overload protection test, over-current protection test, power factor test, grid current harmonic test, resonance point test, and so on. Both Leading power factor (Capacitive) and lagging power factor (Inductive) could be available with RLC AC load banks.
Only at Rexgear