Programmable RLC Load Bank

$0.00

Required
Required
Required
Required
Required
Your message has been sent! We will contact you as soon as possible Monday - Friday 9 am to 5 pm (PST). In the meantime, we invite you to read our blog news.

REXGEAR RLC load bank testing solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC/DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.

RLC load banks applications

  • Battery bank system
  • Energy storage system
  • Energy meter loop load test
  • Datacenter rack heat simulating
  • PV system Inverter anti-islanding test
  • Voltage regulator, rectifier aging load test
  • Genset, UPS load bank commission testing

RLC load banks loading elements (load bank types)

Alloy resistors, inductors & capacitors loading elements are combined used in RLC load bank as per clients’ need in different applications:

  • Pure resistive AC load bank
  • Pure resistive DC load bank
  • RCD non-linear AC load bank
  • Resistive & inductive combined AC load bank
  • Resistive, inductive & capacitive combined AC load bank

Technical Specifications

Model Resistive, Inductive & Capacitive AC Load Bank

Load Element

Stainless steel resistors, Inductor & Capacitor

Load Voltage

3φ4W+G, Y connection:

110/190V,115/200V, 120/208V,128/220V,132/230V,139/240V

220/380V, 230/400V, 240/415V, 254/440V, 265/460V, 277/480V

(Or other load voltage upon request)

Frequency

50/60Hz

Load Power

R(resistive power): upon request

L(inductive power): upon request

C(capacitive power): upon request

Minimum Load Steps

Resistive load step: 10W

Inductive load step: 10Var

Capacitive load step: 10Var

(Or other load step upon request)

Power Factor

PF=Leading & lagging 0-1.0 adjustable

Load Accuracy

R: ±5%, L: ±10%, C: ±5%

Digital Meter

voltage, current, active power, reactive power, apparent power,
power factor, energy, frequency

Mains Power Supply

1phase 2wire 50/60Hz: AC120V/220V/230V/240V

3phase 4wire 50/60Hz: AC208V/380V/400V/415V

2 Control Modes

1- Manual control by push button

2- PC software remote control

Wire Connections

Copper bus bar for wire connections

Insulation Class

F

Fan Noise

75-90dB

Cooling Mode

Force-air vertical or horizontal cooling

Work Mode

Continuous work

Protections

Overheating/buzzer alarm, overheating/over voltage/current protection,

emergency stop button

Ambient Temperature

10℃~+50℃

Mobility

By wheels or stationary with forklift pocket

Humidity

≤95%

Altitude

≤2500 meters

RLC load banks protections

Standard protections:

  • Emergency pause operation: one-key stop loading
  • Over temperature alarm/protection: alarm & remove load
  • Fan interlock protection: loading available after fan activated
  • Over voltage protection: alarm & remove load

Optional protections

  • Blower thermal overload protection: alarm & remove load
  • Short circuit protection by fuse (over current protection)
  • Phase sequence protection (for fans with 3phase voltage)
  • Or other functions as requested
 

RLC load bank control modes

Two control modes available for RLC load banks: The local panel control mode and the PC software remote control mode.

Local panel control mode available as below listed:

  • By contactor
  • By circuit breakerOr other switches as requested

PC software remote control (optional)

RLC load bank remote control communication protocol would be provided for clients’ integrating the load bank into the ATE system

Resistive, Inductive & Capacitive AC Load Bank (RLC)

RLC load banks are mostly used for inverter anti-islanding test experiments which meets the PV & grid inverter testing requirements for islanding prevention detection, work efficiency test, overload protection test, over-current protection test, power factor test, grid current harmonic test, resonance point test, and so on.

Both Leading power factor (Capacitive) and lagging power factor (Inductive) could be available with RLC AC load banks.

Please Contact Us for the Following

Please Contact Us for the Following

  • Product selection, customization
  • Data sheets, user manual, software
  • Technical support, code troubleshooting
  • Warranty, calibration, service plans

Only at Rexgear

Dedicated Engineer
Helping you select the ideal hardware & software with confidence.

Customized Equipment
Change resistance regulation to 0 ~ 10 Ω before shipping the unit?

Short Lead Time
Even on special orders & custom made power supplies.

Technical Support
Cut off current at a certain voltage with a feedback loop in Matlab?

2-Year Warranty
Buy with confidence.

Fast Delivery
To Mexico and United States in 5-8 days.

When choosing an industrial equipment, It is essential to work with experts who have had actual experience installing, using, and repairing them. This puts us in the top 2% of the authorized distributors and service providers.